AERIS ZENITH BREATHING EQUIPMENT

Open circuit Type 2 intervention equipment.

Description

Type 2 open-circuit intervention equipment with an automatic positive-pressure demand valve, a mask with a voice membrane, and an anti-scratch visor. Photoluminescent pressure gauge with integrated alarm. The materials used combine comfort with high performance and are specifically designed for firefighters and industry.

ESPALIER

Semi-rigid, ergonomic back plate. Three carrying handles and a lifeline attachment point. Comfortable aramid fiber padding on the shoulder and waist straps. The weight is distributed across the hips for greater freedom of movement. Adjustable, quick-release shoulder buckles. Washable harness.

REDUCER

Arial model, with an integrated outlet for a second user, allowing the addition of an air supply for an additional rescue hood, full face mask, or airline connection. It includes a safety valve rated at 12-15 bar.

LUNCH

Zenith model. The valve is automatically activated when connected to the mask and closes when disconnected. The low breathing resistance ensures excellent respiratory performance under any workload. It features two attachment points.

MASK

Panoramasque model with anti-chlorine and anti-scratch visor. Incorporates a speech membrane and positive-pressure exhalation valve. Five-point octopus head attachment system. Neck strap for hands-free carrying.

BOTTLES

The compressed air cylinders commonly used are made of steel and are supplied with a charging pressure of 300 bar and a capacity of 6 litres, which provides an air volume of 1,800 litres and an autonomy at average consumption (40 l/min.) of 45 minutes.

Technical characteristics

WEIGHT (WITHOUT CYLINDER)

4.1 kg (With mask)

INLET PRESSURE

0-300 bar

OUTLET PRESSURE 1ST STAGE

7 bar static pressure.

PULMO ZENITH

Max flow rate 300 l/min.

Static pressure 3 millibar.

PRESSURE GAUGE

Bourdon tube with analogue indicator, range 0 – 400 bar, with rubber protector.

ALARM

Activation 55 bar ± 5 bar > 90 dBA. Pneumatic.

MASK

Static pressure 3 millibar. Weight approximately 585 g. EN 136 Class III

CERTIFICATIONS

CE 0194/0060, EN 137:2006 Type 2, SOLAS, MED, IMO, MSC

Accessories

ZENITH SECOND EXIT

2nd output hose to connect rescue equipment, a second user with a mask and lungs, or an external air line to work as a semi-autonomous device.

REFLECTIVES

Two reflective strips on the shoulder harness for greater visibility in areas with reduced visibility.

Documentation

Technical sheet