AERIS ZENITH BREATHING EQUIPMENT

Open circuit Type 2 intervention team.

Description

Type 2 open-circuit intervention equipment, with automatic positive pressure demand valve, mask with voice diaphragm and scratch-resistant visor. Photoluminescent pressure gauge with integrated alarm. The materials used combine comfort with high performance and it is specially designed for firefighters and industrial use.

ESPALIER

Semi-rigid, ergonomic backplate. Three carrying handles and a lifeline attachment point. Comfortable aramid fiber shoulder and waist strap padding. Weight is distributed across the hips for greater freedom of movement. Adjustable, quick-release shoulder buckles. Washable harness.

REDUCER

The Arial model features an integrated outlet for a second user, allowing for the addition of an air supply for an additional rescue hood, full face mask, or air line connection. It incorporates a safety valve set at 12-15 bar.

LUNG

Zenith model. The valve activates automatically when connected to the mask and closes when disconnected. Low breathing resistance ensures excellent respiratory performance under any work demands. It features two attachment points.

MASK

Panoramasque model with visor featuring anti-chlorine and anti-scratch treatment. Includes a sound diaphragm and positive pressure exhalation valve. Head attachment system with a 5-point bungee cord. Neck strap for hands-free carrying.

BOTTLES

The compressed air bottles commonly used are made of steel and are supplied with a charging pressure of 300 bar with a capacity of 6 liters, which facilitates an air volume of 1,800 liters and an autonomy at average consumption (40 l/min.) of 45 minutes.

Technical characteristics

WEIGHT (WITHOUT CYLINDER)

4.1 kg (With mask)

INLET PRESSURE

0-300 bar

OUTLET PRESSURE 1ST STAGE

7 bar static pressure.

LUNG ZENITH

Max. flow rate 300 l/min.

Static pressure 3 millibar.

PRESSURE GAUGE

Bourdon tube with analog indicator, range 0 – 400 bar, with rubber protector.

ALARM

Activation 55 bar ± 5 bar > 90 dBA. Pneumatic.

MASK

Static pressure 3 millibar. Weight approximately 585 g. EN 136 Class III

CERTIFICATIONS

CE 0194/0060, EN 137:2006 Type 2, SOLAS, MED, IMO, MSC